| Commit message (Collapse) | Author | Age | Lines |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Two new options:
CONFIG_PL011_SERIAL_RLCR
Some vendor versions of PL011 serial ports (e.g. ST-Ericsson U8500)
have separate receive and transmit line control registers. Set
this variable to initialize the extra register.
CONFIG_PL011_SERIAL_FLUSH_ON_INIT
On some platforms (e.g. U8500) U-Boot is loaded by a second stage
boot loader that has already initialized the UART. Define this
variable to flush the UART at init time.
empty fifo on init
Signed-off-by: John Rigby <john.rigby@linaro.org>
Signed-off-by: Rabin Vincent <rabin.vincent@stericsson.com>
|
|
|
|
|
|
|
|
| |
Use C structs for registers, and use readl/writel instead of custom
accessors.
Acked-by: Michael Brandt <michael.brandt@stericsson.com>
Signed-off-by: Rabin Vincent <rabin.vincent@stericsson.com>
|
|
They only differ in the init function.
This also adds the missing watchdog support for the PL011.
Signed-off-by: Andreas Engel <andreas.engel@ericsson.com>
|