| Commit message (Collapse) | Author | Age | Lines |
|
|
|
|
|
|
|
|
| |
Add support to handle enable-active-high DT property. This property is
used to drive the gpio controlling fixed regulator as active high when
claiming gpio line.
Signed-off-by: Vignesh R <vigneshr@ti.com>
Acked-by: Simon Glass <sjg@chromium.org>
|
|
|
|
|
|
|
|
|
|
|
| |
According to the binding documentation the fixed regulator enable GPIO
is optional. However so far registration thereof failed if no enable
GPIO was specified. Fix this by making it entirely optional whether an
enable GPIO is used.
Signed-off-by: Marcel Ziswiler <marcel.ziswiler@toradex.com>
Acked-by: Stephen Warren <swarren@nvidia.com>
Signed-off-by: Tom Warren <twarren@nvidia.com>
|
|
|
|
|
|
|
|
|
|
| |
When enabling a fixed regulator, it may take some time to rise to the
correct voltage. If we do not delay here then subsequent operations
will fail.
Signed-off-by: John Keeping <john@metanate.com>
Reviewed-by: Tom Rini <trini@konsulko.com>
Reviewed-by: Simon Glass <sjg@chromium.org>
|
|
This driver implements regulator operations for fixed Voltage/Current
value regulators. beside the standard regulator constraints, which are
put into the uclass platform data, a typical fixed regulator node provides
few additional properties like:
- gpio
- gpio-open-drain
- enable-active-high
- startup-delay-us
The only 'gpio' is used by this driver and is kept in structure of type
'fixed_regulator_platdata', as a device platform data (dev->platdata).
The driver implements:
- get_value
- get_current
- get_enable
- set_enable
The regulator calls and commands can be used for fixed-regulator devices,
and the proper error will be returned for prohibited.
Signed-off-by: Przemyslaw Marczak <p.marczak@samsung.com>
Acked-by: Simon Glass <sjg@chromium.org>
|