| Commit message (Collapse) | Author | Age | Lines |
|
|
|
|
|
|
| |
A previous operation may have set the error flag, which must be cleared
before a new write operation can be issued.
Signed-off-by: Hector Palacios <hector.palacios@digi.com>
|
|
|
|
|
|
|
|
|
| |
The write operation may fail when trying to write to a locked area. In
this case the ERROR bit is set in the CTRL register. Check for that
condition and return an error.
Signed-off-by: Hector Palacios <hector.palacios@digi.com>
Reviewed-by: Fabio Estevam <fabio.estevam@freescale.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
The code may goto 'fail' upon error with 'ret' variable set to an error
code, but this variable was being overwritten by a final preparation
function to restore the HCLK, so success was (in general) returned even
after an error was hit previously.
With this change, the function may now return success even if the final
preparation function fails, but it's probably enough to print a message
because (if successful) the real programming of the fuses has already
completed.
Signed-off-by: Hector Palacios <hector.palacios@digi.com>
|
|
Add yet another OCOTP driver for this i.MX family. This time, it's a driver for
the OCOTP variant found in the i.MX23 and i.MX28. This version of OCOTP is too
different from the i.MX6 one that I could not use the mxc_ocotp.c driver without
making it into a big pile of #ifdef . This driver implements the regular fuse
command interface, but due to the IP blocks' limitation, we support only READ
and PROG functions.
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: Stefano Babic <sbabic@denx.de>
|