| Commit message (Collapse) | Author | Age | Lines |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
On AD7414 the first value upon bootup is not read correctly.
This is most likely because of the 800ms update time of the
temp register in normal update mode. To get current values
each time we issue the "dtt" command including upon powerup
we switch into one-short mode.
This patch fixes the problem on AD7414 equipped boards (Sequoia,
Canyonlands etc), that temp value printed in the bootup log was
incorrect.
Signed-off-by: Stefan Roese <sr@denx.de>
|
|
|
|
|
|
|
|
|
| |
When the LM73 temperature sensor measures a temperature below 0 C, the
current driver does not perform sign extension, so the result returned is
512 C too high. This patch fixes the problem, and does general cleanup
of the code.
Signed-off-by: Larry Johnson <lrj@acm.org>
|
|
|
|
|
|
|
|
| |
When the LM75 temperature sensor measures a temperature below 0 C, the
current driver does not perform sign extension, so the result returned is
256 C too high. This patch fixes the problem.
Signed-off-by: Larry Johnson <lrj@acm.org>
|
|
|
|
|
|
|
|
| |
(1) Remove unused symbol "CFG_EEPROM_PAGE_WRITE_ENABLE".
(2) Use conditional Makefile.o.
Signed-off-by: Larry Johnson <lrj@acm.org>
|
|
|
|
|
|
| |
This driver is based on the driver for the LM75.
Signed-off-by: Larry Johnson <lrj@acm.org>
|
|
|
|
|
|
| |
Conflicts:
drivers/rtc/Makefile
|
|
Signed-off-by: Jean-Christophe PLAGNIOL-VILLARD <plagnioj@jcrosoft.com>
|