On AMCC Arches board DTT_I2C_DEV_CODE is different then canyonlands
and glacier.
Signed-off-by: Victor Gallardo <vgallardo@amcc.com>
|
|
|
|
|
|
|
|
| |
Clean Makefile
Move device specific values to driver for better reading
Signed-off-by: Michal Simek <monstr@monstr.eu>
Acked-by: Stefan Roese <sr@denx.de>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
On AD7414 the first value upon bootup is not read correctly.
This is most likely because of the 800ms update time of the
temp register in normal update mode. To get current values
each time we issue the "dtt" command including upon powerup
we switch into one-short mode.
This patch fixes the problem on AD7414 equipped boards (Sequoia,
Canyonlands etc), that temp value printed in the bootup log was
incorrect.
Signed-off-by: Stefan Roese <sr@denx.de>
|
|
|
|
|
|
|
|
| |
When the LM75 temperature sensor measures a temperature below 0 C, the
current driver does not perform sign extension, so the result returned is
256 C too high. This patch fixes the problem.
Signed-off-by: Larry Johnson <lrj@acm.org>
|
|