| Commit message (Collapse) | Author | Age | Lines |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
"reset.c" and "cpu.c" have no architecture-specific code at all.
Others are applicable to either ARC CPU.
This change is a preparation to submission of ARCv2 architecture port.
Even though ARCv1 and ARCv2 ISAs are not binary compatible most of
built-in modules still have the same programming model - AUX registers
are mapped in the same addresses and hold the same data (new featues
extend existing ones).
So only low-level assembly code (start-up, interrupt handlers) is left
as CPU(actually ISA)-specific. This significantyl simplifies maintenance
of multiple CPUs/ISAs.
Signed-off-by: Alexey Brodkin <abrodkin@synopsys.com>
Signed-off-by: Igor Guryanov <guryanov@synopsys.com>
|
|
|
|
|
|
|
|
|
|
| |
* use better symbols for relocatable region boundaries
("__image_copy_start" instead of "CONFIG_SYS_TEXT_BASE")
* remove useless debug messages because they will only show up in case
of both problem (when normal "if" branch won't be taken) and DEBUG take
place which is pretty rare situation.
Signed-off-by: Alexey Brodkin <abrodkin@synopsys.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Even though existing implementation works fine in preparation to
submission of ARCv2 architecture we need this change.
In case of ARCv2 interrupt vector table consists of just addresses
of corresponding handlers. And if those addresses will be in .text
section then assembler will encode them as everything in .text section
as middle-endian and then on real execution CPU will read swapped
addresses and will jump into the wild.
Once introduced new section is situated so .text section remains the
first which allows us to use common linker option for linking everything
to a specified CONFIG_SYS_TEXT_BASE.
Signed-off-by: Alexey Brodkin <abrodkin@synopsys.com>
Signed-off-by: Igor Guryanov <guryanov@synopsys.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
In case of little-endian ARC700 instructions (which may include target
address) are encoded as middle-endian. That's why it's required to swap
bytes after read and ten right before write back.
But in case of big-endian ARC700 instructions are encoded as a plain
big-endian. Thus no need for byte swapping.
Signed-off-by: Alexey Brodkin <abrodkin@synopsys.com>
Cc: Francois Bedard <fbedard@synopsys.com>
Cc: Tom Rini <trini@ti.com>
cc: Noam Camus <noamc@ezchip.com>
|
|
These are library functions used by ARC700 architecture.
Signed-off-by: Alexey Brodkin <abrodkin@synopsys.com>
Cc: Vineet Gupta <vgupta@synopsys.com>
Cc: Francois Bedard <fbedard@synopsys.com>
Cc: Wolfgang Denk <wd@denx.de>
Cc: Heiko Schocher <hs@denx.de>
|