summaryrefslogtreecommitdiff
path: root/doc
diff options
context:
space:
mode:
Diffstat (limited to 'doc')
-rw-r--r--doc/README.mpc85xxcds53
1 files changed, 26 insertions, 27 deletions
diff --git a/doc/README.mpc85xxcds b/doc/README.mpc85xxcds
index 06b1e98..e0f4916 100644
--- a/doc/README.mpc85xxcds
+++ b/doc/README.mpc85xxcds
@@ -6,7 +6,7 @@ The CDS family of boards consists of a PCI backplane called the
and a CPU daughter card that bolts onto the daughter card.
Much of the content of the README.mpc85xxads for the 85xx ADS boards
-applies to the 85xx CDS boards as well. In particular the toolchain,
+applies to the 85xx CDS boards as well. In particular the toolchain,
the switch nomenclature, and the basis for the memory map. There are
some differences, though.
@@ -33,16 +33,16 @@ map.
The mapping is:
- 0x0000_0000 0x7fff_ffff DDR 2G
- 0x8000_0000 0x9fff_ffff PCI1 MEM 512M
- 0xa000_0000 0xbfff_ffff PCI2 MEM 512M
- 0xe000_0000 0xe00f_ffff CCSR 1M
- 0xe200_0000 0xe2ff_ffff PCI1 IO 16M
- 0xe300_0000 0xe3ff_ffff PCI2 IO 16M
- 0xf000_0000 0xf7ff_ffff SDRAM 128M
- 0xf800_0000 0xf80f_ffff NVRAM/CADMUS (*) 1M
- 0xff00_0000 0xff7f_ffff FLASH (2nd bank) 8M
- 0xff80_0000 0xffff_ffff FLASH (boot bank) 8M
+ 0x0000_0000 0x7fff_ffff DDR 2G
+ 0x8000_0000 0x9fff_ffff PCI1 MEM 512M
+ 0xa000_0000 0xbfff_ffff PCI2 MEM 512M
+ 0xe000_0000 0xe00f_ffff CCSR 1M
+ 0xe200_0000 0xe2ff_ffff PCI1 IO 16M
+ 0xe300_0000 0xe3ff_ffff PCI2 IO 16M
+ 0xf000_0000 0xf7ff_ffff SDRAM 128M
+ 0xf800_0000 0xf80f_ffff NVRAM/CADMUS (*) 1M
+ 0xff00_0000 0xff7f_ffff FLASH (2nd bank) 8M
+ 0xff80_0000 0xffff_ffff FLASH (boot bank) 8M
(*) The system control registers (CADMUS) start at offset 0xfdb0_4000
within the NVRAM/CADMUS region of memory.
@@ -67,9 +67,9 @@ it into the secondary bank:
loadb
[Drop to kermit:
- ^\c
- send <u-boot-bin-image>
- c
+ ^\c
+ send <u-boot-bin-image>
+ c
]
erase ff780000 ff7fffff
@@ -102,10 +102,10 @@ The first two bits of SW2 control how flash is used on the board:
12345678
--------
- SW2=00XXXXXX FLASH: Boot bank 1, bank 2 available.
- 01XXXXXX FLASH: Boot bank 2, bank 1 available (swapped).
- 10XXXXXX FLASH: Boot promjet, bank 1 available
- 11XXXXXX FLASH: Boot promjet, bank 2 available
+ SW2=00XXXXXX FLASH: Boot bank 1, bank 2 available.
+ 01XXXXXX FLASH: Boot bank 2, bank 1 available (swapped).
+ 10XXXXXX FLASH: Boot promjet, bank 1 available
+ 11XXXXXX FLASH: Boot promjet, bank 2 available
The boot bank is always mapped to FF80_0000 and listed first by
the "flinfo" command. The secondary bank is always FF00_0000.
@@ -116,10 +116,10 @@ convey this information:
12345678
--------
- SW2=xxxxxx00 PCI SLOT INFORM: The CDS carrier is in slot0 of the Arcadia
- xxxxxx01 PCI SLOT INFORM: The CDS carrier is in slot1 of the Arcadia
- xxxxxx10 PCI SLOT INFORM: The CDS carrier is in slot2 of the Arcadia
- xxxxxx11 PCI SLOT INFORM: The CDS carrier is in slot3 of the Arcadia
+ SW2=xxxxxx00 PCI SLOT INFORM: The CDS carrier is in slot0 of the Arcadia
+ xxxxxx01 PCI SLOT INFORM: The CDS carrier is in slot1 of the Arcadia
+ xxxxxx10 PCI SLOT INFORM: The CDS carrier is in slot2 of the Arcadia
+ xxxxxx11 PCI SLOT INFORM: The CDS carrier is in slot3 of the Arcadia
These are cleverly, er, clearly silkscreened as Slot 1 through 4,
respectively, on the Arcadia near the support posts.
@@ -130,7 +130,7 @@ The default setting of all switches on the carrier board is:
12345678
--------
SW1=01101100
- SW2=0x1111yy x=Flash bank, yy=PCI slot
+ SW2=0x1111yy x=Flash bank, yy=PCI slot
SW3=11101111
SW4=10001000
@@ -178,10 +178,9 @@ Commands for downloading a u-boot image to memory from edink:
time -s 4/8/2004 4:30p
dl -k -b -o 100000
[Drop to kermit:
- ^\c
- transmit /binary <u-boot-bin-image>
- c
+ ^\c
+ transmit /binary <u-boot-bin-image>
+ c
]
fu -l 100000 fe780000 80000
-