diff options
author | Stephen Warren <swarren@nvidia.com> | 2014-04-18 10:56:11 -0600 |
---|---|---|
committer | Tom Warren <twarren@nvidia.com> | 2014-05-13 10:41:31 -0700 |
commit | f175603f7c4fe614c913476bfec78a36ae8be7a3 (patch) | |
tree | 297ef17e72e08df2ee4692ef7ee5721606929496 /drivers/mmc/tegra_mmc.c | |
parent | d2a3e911390f9fc4d8c0ee4b3c7fc75f4fd3fd19 (diff) | |
download | u-boot-imx-f175603f7c4fe614c913476bfec78a36ae8be7a3.zip u-boot-imx-f175603f7c4fe614c913476bfec78a36ae8be7a3.tar.gz u-boot-imx-f175603f7c4fe614c913476bfec78a36ae8be7a3.tar.bz2 |
ARM: tegra: set CONFIG_SYS_MMC_MAX_DEVICE
If CONFIG_API is ever to be enabled on Tegra, this define must be set,
since api/api_storage.c uses it.
A couple of annoyting things about CONFIG_SYS_MMC_MAX_DEVICE
1) It isn't documented in README. The same is true for a lot of similar
defines used by api_storage.c.
2) It doesn't represent MAX_DEVICE but rather NUM_DEVICES, since the
valid values are 0..n-1 not 0..n.
However, I this patch does not address those shortcomings.
Signed-off-by: Stephen Warren <swarren@nvidia.com>
Signed-off-by: Tom Warren <twarren@nvidia.com>
Diffstat (limited to 'drivers/mmc/tegra_mmc.c')
-rw-r--r-- | drivers/mmc/tegra_mmc.c | 13 |
1 files changed, 8 insertions, 5 deletions
diff --git a/drivers/mmc/tegra_mmc.c b/drivers/mmc/tegra_mmc.c index ed67eec..ca9c4aa 100644 --- a/drivers/mmc/tegra_mmc.c +++ b/drivers/mmc/tegra_mmc.c @@ -18,7 +18,7 @@ DECLARE_GLOBAL_DATA_PTR; -struct mmc_host mmc_host[MAX_HOSTS]; +struct mmc_host mmc_host[CONFIG_SYS_MMC_MAX_DEVICE]; #ifndef CONFIG_OF_CONTROL #error "Please enable device tree support to use this driver" @@ -669,13 +669,14 @@ static int process_nodes(const void *blob, int node_list[], int count) void tegra_mmc_init(void) { - int node_list[MAX_HOSTS], count; + int node_list[CONFIG_SYS_MMC_MAX_DEVICE], count; const void *blob = gd->fdt_blob; debug("%s entry\n", __func__); /* See if any Tegra124 MMC controllers are present */ count = fdtdec_find_aliases_for_id(blob, "sdhci", - COMPAT_NVIDIA_TEGRA124_SDMMC, node_list, MAX_HOSTS); + COMPAT_NVIDIA_TEGRA124_SDMMC, node_list, + CONFIG_SYS_MMC_MAX_DEVICE); debug("%s: count of Tegra124 sdhci nodes is %d\n", __func__, count); if (process_nodes(blob, node_list, count)) { printf("%s: Error processing T30 mmc node(s)!\n", __func__); @@ -684,7 +685,8 @@ void tegra_mmc_init(void) /* See if any Tegra30 MMC controllers are present */ count = fdtdec_find_aliases_for_id(blob, "sdhci", - COMPAT_NVIDIA_TEGRA30_SDMMC, node_list, MAX_HOSTS); + COMPAT_NVIDIA_TEGRA30_SDMMC, node_list, + CONFIG_SYS_MMC_MAX_DEVICE); debug("%s: count of T30 sdhci nodes is %d\n", __func__, count); if (process_nodes(blob, node_list, count)) { printf("%s: Error processing T30 mmc node(s)!\n", __func__); @@ -693,7 +695,8 @@ void tegra_mmc_init(void) /* Now look for any Tegra20 MMC controllers */ count = fdtdec_find_aliases_for_id(blob, "sdhci", - COMPAT_NVIDIA_TEGRA20_SDMMC, node_list, MAX_HOSTS); + COMPAT_NVIDIA_TEGRA20_SDMMC, node_list, + CONFIG_SYS_MMC_MAX_DEVICE); debug("%s: count of T20 sdhci nodes is %d\n", __func__, count); if (process_nodes(blob, node_list, count)) { printf("%s: Error processing T20 mmc node(s)!\n", __func__); |