diff options
author | Simon Glass <sjg@chromium.org> | 2013-05-16 13:53:22 +0000 |
---|---|---|
committer | Tom Rini <trini@ti.com> | 2013-06-04 16:06:31 -0400 |
commit | a51ec63b85edbc6f8987069d0a60eec09d4f35c8 (patch) | |
tree | 364d706b98d3a65ba484611ff0c14d38ab0e822c /common/image-fit.c | |
parent | 782cfbb25900797651be8876e834da1d12e0c68d (diff) | |
download | u-boot-imx-a51ec63b85edbc6f8987069d0a60eec09d4f35c8.zip u-boot-imx-a51ec63b85edbc6f8987069d0a60eec09d4f35c8.tar.gz u-boot-imx-a51ec63b85edbc6f8987069d0a60eec09d4f35c8.tar.bz2 |
image: Use fit_image_load() to load ramdisk
Use the new common code to load a ramdisk. The functionality should not
change.
Signed-off-by: Simon Glass <sjg@chromium.org>
Diffstat (limited to 'common/image-fit.c')
-rw-r--r-- | common/image-fit.c | 62 |
1 files changed, 0 insertions, 62 deletions
diff --git a/common/image-fit.c b/common/image-fit.c index 9f56b5d..16fb196 100644 --- a/common/image-fit.c +++ b/common/image-fit.c @@ -1371,25 +1371,6 @@ int fit_conf_get_kernel_node(const void *fit, int noffset) } /** - * fit_conf_get_ramdisk_node - get ramdisk image node offset that corresponds to - * a given configuration - * @fit: pointer to the FIT format image header - * @noffset: configuration node offset - * - * fit_conf_get_ramdisk_node() retrives ramdisk image node unit name from - * configuration FIT_KERNEL_PROP property and translates it to the node - * offset. - * - * returns: - * image node offset when found (>=0) - * negative number on failure (FDT_ERR_* code) - */ -int fit_conf_get_ramdisk_node(const void *fit, int noffset) -{ - return fit_conf_get_prop_node(fit, noffset, FIT_RAMDISK_PROP); -} - -/** * fit_conf_get_fdt_node - get fdt image node offset that corresponds to * a given configuration * @fit: pointer to the FIT format image header @@ -1467,49 +1448,6 @@ int fit_image_select(const void *fit, int rd_noffset, int verify) return 0; } -/** - * fit_check_ramdisk - verify FIT format ramdisk subimage - * @fit_hdr: pointer to the FIT ramdisk header - * @rd_noffset: ramdisk subimage node offset within FIT image - * @arch: requested ramdisk image architecture type - * @verify: data CRC verification flag - * - * fit_check_ramdisk() verifies integrity of the ramdisk subimage and from - * specified FIT image. - * - * returns: - * 1, on success - * 0, on failure - */ -int fit_check_ramdisk(const void *fit, int rd_noffset, uint8_t arch, - int verify) -{ - fit_image_print(fit, rd_noffset, " "); - - if (verify) { - puts(" Verifying Hash Integrity ... "); - if (!fit_image_verify(fit, rd_noffset)) { - puts("Bad Data Hash\n"); - bootstage_error(BOOTSTAGE_ID_FIT_RD_HASH); - return 0; - } - puts("OK\n"); - } - - bootstage_mark(BOOTSTAGE_ID_FIT_RD_CHECK_ALL); - if (!fit_image_check_os(fit, rd_noffset, IH_OS_LINUX) || - !fit_image_check_arch(fit, rd_noffset, arch) || - !fit_image_check_type(fit, rd_noffset, IH_TYPE_RAMDISK)) { - printf("No Linux %s Ramdisk Image\n", - genimg_get_arch_name(arch)); - bootstage_error(BOOTSTAGE_ID_FIT_RD_CHECK_ALL); - return 0; - } - - bootstage_mark(BOOTSTAGE_ID_FIT_RD_CHECK_ALL_OK); - return 1; -} - int fit_get_node_from_config(bootm_headers_t *images, const char *prop_name, ulong addr) { |